v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x806f0107 806f0021-1001ffff
806f0021-1002ffff
806f0021-1003ffff
806f0021-1004ffff
0x806f0021 806f0021-2582ffff
144
BladeCenter HS23E Type 8038 and 8039: Problem Determination and Service Guide
Type
Error Message
Error
Expansion Module,
Fault in (Slot Y) on
(BPE4_X, [Note:
X=1-4, Y=1, 2]
Error
PCI error (All PCI
Error)
Action
1. Check the event logs for other related
error messages (see "Event logs" on
page 96).
2. Verify that you have the latest system
firmware (see "Updating firmware and
device drivers" on page 31).
3. Run the Setup utility and restore system
setting to defaults (see "Using the Setup
utility" on page 18).
4. Check the event logs for other related
error messages (see "Event logs" on
page 96).
5. Reseat the expansion cards and PCIe
adapters that are installed in the blade
server (see "Removing an I/O
expansion card" on page 71 and
"Installing an I/O expansion card" on
page 73).
6. Reseat the expansion unit.
7. Remove each expansion card, one at a
time until the error does not occur (see
"Removing an I/O expansion card" on
page 71).
8. Replace failing adapter and reinstall any
other expansion cards that were
removed (see "Installing an I/O
expansion card" on page 73).
9. Replace the expansion unit (see
"Removing an optional expansion unit"
on page 79 and "Installing an optional
expansion unit" on page 80).
10. If the system contains multiple
microprocessors, swap the
microprocessors (see "Removing a
microprocessor and heat sink" on page
81 and "Installing a microprocessor and
heat sink" on page 84).
11. (Trained technician only) If the error
continues, replace the system-board
assembly (see "Removing the
system-board assembly" on page 90 and
"Installing the system-board assembly"
on page 91).
This is a UEFI detected event. The UEFI
diagnostic code for this event can be found
in the logged IMM message text. Please refer
to "UEFI/POST error codes" on page 99 for
the appropriate actions.