v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x806f0007 806f0007-0301ffff
806f0007-0302ffff
0x806f0009 806f0009-1301ffff
0x806f000d 806f000d-0400ffff
806f000d-0401ffff
0x806f000f
806f000f-220101xx
0x806f000f
806f000f-220102xx
Type
Error Message
Error
Processor X (CPU
X) has Failed with
IERR. [Note X=1,2]
Info
Sensor (Host
Power) has been
turned off.
Error
Hard drive X,
(Drive X) removed
[Note X=0,1]
Error
FW/BIOS, firmware
error. The System
(ABR Status) has
detected no
memory in the
system.
Error
FW/BIOS, firmware
error. Subsystem
(ABR Status) has
insufficient memory
for operation.
Action
1. Remove the blade server and ensure the
processors are installed correctly (see
"Installing a microprocessor and heat
sink" on page 84).
2. Verify that the system is running the
latest UEFI firmware (see "Updating
firmware and device drivers" on page
31).
3. Run the Setup utility (see "Using the
Setup utility" on page 18).
a. Make sure that both processors are
displayed by the system.
b. Load the default settings.
c. Go to the System Settings menu and
make sure the processor is enabled.
4. (Trained technician only) If the problem
continues, replace the processor (see
"Removing a microprocessor and heat
sink" on page 81 and "Installing a
microprocessor and heat sink" on page
84).
5. (Trained technician only) If the error
continues, replace the system-board
assembly (see "Removing the
system-board assembly" on page 90 and
"Installing the system-board assembly"
on page 91).
Information only; no action is required.
Install the storage drive (see "Installing a
hot-swap storage drive" on page 64).
Install the latest UEFI firmware (see
"Recovering from a UEFI update failure" on
page 217).
Install the latest UEFI firmware (see
"Recovering from a UEFI update failure" on
page 217).