v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are
consumable, structural, or CRU parts.
v If an action step is preceded by "(Trained technician only)," that step must be
performed only by a trained technician.
Diagnostic
code
Message
W.305000A [W.305000A] An
invalid date and
time have been
detected.
S.3058004
[S.3058004] A Three
Strike boot failure
has occurred. The
system has booted
with default UEFI
settings.
Description
Action
RTC Date and
1. Run the Setup utility (see "Using
Time Incorrect.
the Setup utility" on page 18).
Select Load Default Settings and
save the settings.
2. Reseat the battery (see
"Removing the battery" on page
61 and "Installing the battery" on
page 62).
3. Replace the battery (see
"Removing the battery" on page
61 and "Installing the battery" on
page 62).
POST failure has
1. Undo any recent system changes,
occurred! System
such as new settings or newly
booted with
installed devices.
default settings.
2. Make sure that the server is
attached to a reliable power
source.
3. Remove all hardware that is not
supported by the server (see
http://www.ibm.com/systems/
info/x86servers/serverproven/
compat/us/ ).
4. Update the firmware to the latest
level (see "Updating firmware
and device drivers" on page
31for more information).
5. Make sure that the operating
system is not corrupt.
6. Run the Setup utility, save the
configuration, and then restart
the server.
7. (Trained technician only) If the
problem remains, replace the
system board (see "Removing the
system-board assembly" on page
90 and "Installing the
system-board assembly" on page
91).
121