120
BladeCenter HS23E Type 8038 and 8039: Problem Determination and Service Guide
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are
consumable, structural, or CRU parts.
v If an action step is preceded by "(Trained technician only)," that step must be
performed only by a trained technician.
Diagnostic
code
Message
S.3040007
[S.3040007] A
firmware fault has
been detected in
the UEFI image.
I.3048005
[I.3048005] UEFI
has booted from
the backup flash
bank.
W.3048006 [W.3048006] UEFI
has booted from
the backup flash
bank due to an
Automatic Boot
Recovery (ABR)
event.
S.3050007
[S.3050007] A
firmware fault has
been detected in
the UEFI image.
Description
Action
Internal UEFI
1. Check the IBM support website
Firmware Fault
for an applicable retain tip or
Detected, System
firmware update that applies to
halted.
this error.
2. Recover the server firmware (see
"Recovering from a UEFI update
failure" on page 217).
3. (Trained technician only) Replace
the system board (see "Removing
the system-board assembly" on
page 90 and "Installing the
system-board assembly" on page
91).
Booting Backup
Information only. Set SW1-5 to the
UEFI Image.
on position to allow the server to
boot from the backup UEFI (see
"System-board switch" on page 13).
Automated Boot
1. Run the Setup utility (see "Using
Recovery, Booting
the Setup utility" on page 18),
Backup UEFI
select Load Default Settings, and
Image.
save the settings.
2. Recover the server firmware (see
"Recovering from a UEFI update
failure" on page 217).
3. (Trained technician only) Replace
the system board (see "Removing
the system-board assembly" on
page 90 and "Installing the
system-board assembly" on page
91).
Internal UEFI
1. Check the IBM support website
Firmware Fault
for an applicable retain tip or
Detected, System
firmware update that applies to
halted.
this error.
2. Recover the server firmware (see
"Recovering from a UEFI update
failure" on page 217).

Advertisement