BladeCenter HS23E Type 8038 and 8039: Problem Determination and Service Guide
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are
consumable, structural, or CRU parts.
v If an action step is preceded by "(Trained technician only)," that step must be
performed only by a trained technician.
Diagnostic
code
Message
I.2018003
[I.2018003] A bad
option ROM
checksum was
detected for the
device found at
Bus % Device %
Function %. The
Vendor ID for the
device is % and the
Device ID is %.
Description
Action
ROM CHECKSUM
1. Run the Setup utility (see "Using
ERROR.
the Setup utility" on page 18).
Select Start Options from the
menu and modify the boot
sequence so that you change the
load order of the optional-device
ROM code.
2. Run the Setup utility (see "Using
the Setup utility" on page 18) and
disable unused resource to make
more space available:
v Select Start Options
v Select Planar Ethernet
v Select Advanced Functions,
v Select Devices and I/O Ports to
3. If the problem remains, replace
the following components one at
a time in the order shown,
restarting the server each time:
v Expansion cards (see
v (Trained technician only)
(PXE/DHCP) to disable the
on-board Ethernet controller
ROM.
followed by PCI Bus Control,
and then PCI ROM Control
Execution to disable the ROM
of the adapters in the PCI slots.
disable any of the on-board
devices.
"Removing an I/O expansion
card" on page 71 and
"Installing an I/O expansion
card" on page 73).
Replace the system board (see
"Removing the system-board
assembly" on page 90 and
"Installing the system-board
assembly" on page 91).