v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x806f0108 806f0108-0701ffff
0x806f0109 806f0109-1301ffff
Type
Error Message
Error
System board,
Power Module
(VRD Fault) failure
(VRD Fault) power
supply failure
detected.
Info
(Host Power) has
been Power Cycled.
Action
1. Make sure that the latest firmware is
being used (see "Updating firmware and
device drivers" on page 31).
2. Reseat the blade server in the
BladeCenter (see "Removing the blade
server from the BladeCenter unit" on
page 49 and "Installing the blade server
in a BladeCenter unit" on page 50).
3. Reset the UEFI firmware settings to
default values using the Setup utility (see
"Using the Setup utility" on page 18).
4. (Trained technician only) Replace the
system-board assembly (see "Removing
the system-board assembly" on page 90
and "Installing the system-board
assembly" on page 91).
Information only; no action is required.
Chapter 6. Diagnostics
147