Lenovo BladeCenter HS23E Problem Determination And Service Manual page 123

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are
consumable, structural, or CRU parts.
v If an action step is preceded by "(Trained technician only)," that step must be
performed only by a trained technician.
Diagnostic
code
Message
S.51009
[S.51009] No
system memory
has been detected.
Description
Action
No Memory
1. Make sure that there is at least
Detected.
one DIMM installed in the server.
2. If there are no memory fault
recorded in the logs and no
DIMM connector error LEDs are
lit, make sure that all DIMM
connectors are enabled by using
the Setup utility or the Advance
Settings Utility (ASU).
3. Reinstall all DIMMs in the correct
population sequence (see
"Installing a memory module" on
page 66 for more information).
109
Chapter 6. Diagnostics