Lenovo BladeCenter HS23E Problem Determination And Service Manual page 145

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x80010900 80010901-2101ffff
0x80010900 80010902-0701ffff
0x80010900 80010902-0701ffff
0x80010900 80010902-0701ffff
Type
Error Message
Error
System mgmt
software (PCH
Temp) temperature
(upper non-critical)
has asserted.
Error
System board
(SysBrd 3.3V)
voltage (upper
critical) has
asserted.
Error
System board
(SysBrd 5V) voltage
(upper critical) has
asserted.
Error
System board
(SysBrd 12V)
voltage (upper
critical) has
asserted.
Action
1. Make sure that the room temperature is
within the operating specifications (see
"Features and specifications" on page 7).
2. Make sure that none of the air vents on
the BladeCenter unit and on the blade
server are blocked.
3. Make sure that all of the fans on the
BladeCenter unit are running.
4. Check the error logs about the
temperature and the fan (see
"UEFI/POST error codes" on page 99).
Replace the blade (see "Removing the
system-board assembly" on page 90 and
"Installing the system-board assembly" on
page 91).
1. Remove all expansion cards from the
blade server (see "Removing an I/O
expansion card" on page 71).
2. Remove all storage drives from the blade
server (see "Removing a hot-swap
storage drive" on page 63).
3.
If the error continues, replace the
system-board assembly (see "Removing
the system-board assembly" on page 90
and "Installing the system-board
assembly" on page 91).
1. If the over voltage problem is occurring
on all blade servers, look for other events
in the log related to power and resolve
those events.
2. View the event log provided by the
advanced management module for your
BladeCenter unit and resolve any power
related errors that might be displayed.
3. If other modules or blades are logging
the same issue then check the power
supply for the BladeCenter unit.
4. If the error continues, replace the
system-board assembly (see "Removing
the system-board assembly" on page 90
and "Installing the system-board
assembly" on page 91).
Chapter 6. Diagnostics
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

80388039

Table of Contents