Alcatel-Lucent 1850 User Provisioning Manual page 576

Transport service switch
Table of Contents

Advertisement

Appendix
............................................................................................................................................................................................................................................................
Command
SET-ATTR-
SECUDFLT
............................................................................................................................................................................................................................................................
6 - 18 2
Description
This is the expiry duration for the
password. When a user logs in
after the PAGE period, he/she will
be notified with the details of the
PCNN and PCND. The user has to
change the password before the
PCND or the PCNN period. The
password aging time is in days.
Default value is 30. Range is
between 0 to 999 days.
Early warning on imminent
password aging. This is the
duration in number of days after
the PAGE, which is allowed for
the user to change his password.
The unit of PCND is in days.
Default value is 7. Range is
between 0 to 999 days.
This is the number of times that a
user can log in after PAGE limit
was reached and before which the
user has to change his password.
Default value 3. Range is between
0 to 999 times.
Password Obsolescence Interval.
This is the minimum time interval
that is required if the User wishes
to use a password that was already
used. Unit of POINT is in days.
Default value is 180. Range is
between 0 to 999 days.
Min Interval between consecutive
invalid attempts, indicates the
minimum interval, in seconds,
between consecutive invalid login
attempts before an NE shall logout
a user and lockout the user
channel.
Max Invalid Attempts, indicates
the maximum number of invalid
login attempts before an NE shall
logout a user and lockout the user
channel.
User Session Activity Link
TimeOut, specifies the amount of
time (in minutes) that the User
Session link is inactive with
regards to user TL1 input before a
user session link time-out occurs.
After the timeout value is reached,
the user will be automatically
Parameter defaults
Parameter
Default
PAGE
<Previously
existing value>
(factory default =
30)
PCND
<Previously
existing value>
(factory default =
7)
PCNN
<Previously
existing value>
(factory default =
3)
POINT
<Previously
existing value>
(factory default
=180)
MININTVL
<Previously
existing value>
(factory default
=15)
MXINV
<Previously
existing value>
(factory default =5)
TMOUT
<Previously
existing value>
(factory default =
8DG08763KAAA
15)
Issue 1 February 2009