Alcatel-Lucent 1850 User Provisioning Manual page 257

Transport service switch
Table of Contents

Advertisement

Tree area
............................................................................................................................................................................................................................................................
Primary State
IS: In Service - The module is
providing service
OOS-AU Out of Service,
Autonomous - the module is out of
service due to an autonomous event
OOS-MA Out of Service,
Management - the module is out of
service due to management action
OOS-AUMA Out of Service,
Autonomous and Management - the
module is out of service both due to
an autonomous event and
management action.
............................................................................................................................................................................................................................................................
8DG08763KAAA
Issue 1 February 2009
Secondary State
AINS Autonomous in service - The module is in
the AINS state and will become in service when
plugged in.
FLT Fault - The module has a Hardware Failure
condition
MEA Mismatch of Equipment and Attributes -
An incompatible module is physically present in
a provisioned slot
PSI Protection Switching Inhibited, by operator
command
SGEO Supporting Entity Outage - reported for
an XFP, SFP or PIM module if the supporting IO
card is in a OOS primary state
SDEE Supported Entities Existing - Reported
for IOC, PIM, SFP and XFP modules that
directly supports provisioned Facilities reported
for all the IOCs modules that don't support
directly any Facilities but that hosts provisioned
Equipment entities that support directly
provisioned Facilities
STBYC Standby-Cold - the module is to back
up another module, but is not synchronized with
the backed-up module. A module with a cold
standby status will not be immediately able to
take over the role of the backed-up module, and
will require some initialization activity
STBYH Standby-Hot - the module is to back-up
another entity and is normally synchronized
with the backed-up module. When In-Service, a
module with a hot standby status will be
immediately able to take over the role of the
backed-up module without the need for
initialization activity
STBYH state will be maintained even when the
entity is OOS. Mutually exclusive with WRK
and STBYC
SWDL Software Download - the module is out
of service because it is in the process of
acquiring, loading, and/or initializing its
software
UAS Unassigned. No equipment is provisioned
in the addressed position
UEQ Unequipped - there is no module in the
addressed position
WRK Working - the module is currently active
and if able, providing service. Mutually
exclusive with STBYH or STBYC
Access a module
4 - 5 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tss-320Tss-160

Table of Contents