Clock Mode Status - Specifies the currently used operation mode for the system
•
timing. The values are LOCKED, AUTONOMOUS-HOLDOVER, AUTONOMOUS-
FREERUNNING, FORCEDFREERUNNING
Sync Messaging - Determines if the timing reference selection for system timing is
•
using sync messaging. The values are Y and N
Alarm Profile - Specifies Alarm Severity Assignment Profile (ASAP) name to be
•
used for the system timing and timing reference entity
Active Reference - Specifies the AID of the currently selected timing reference for the
•
system timing
Reference Switch State - Specifies the currently active switch request state of
•
reference selection for the system timing. The values are NR, MANUAL, and
FORCED
System Timing Quality - Specifies the actual quality value level for the stem timing.
•
The values in SDH mode are PRC, SSUL, SSUT, SEC, and DUS
The Reference Timing Entities table contains the following parameters:
Select - contains a check box used to identify the Access Identifier used with Modify,
•
Operate, and Release
Access Identifier - Specifies timing entity facility
•
Assigned Port Access Identifier - Specifies the Access Identifier of the port
•
Provisioned Quality level - Specifies the provisioned quality level of a timing
•
reference. The values are in SDH mode AUTO, PRC, SSL, SSUT, and SEC
Timing Reference Priority - Specifies the priority of a timing reference as forwarded
•
to the system timing selection process. The values are 0-8
Outgoing Quality - Specifies the actual quality value level for the timing reference as
•
forwarded to the system timing selection process. The values are in SDH mode PRC,
SSUL, SSUT, SEC, and DUS
Timing Reference Status - Specifies the actual signal status for the timing reference
•
as forwarded to the system timing and output timing selection process. The values are
NORMAL, SF, WTR, and NA
Timing Reference Lockout - Specifies whether a lockout command for the system
•
timing selection is present for the timing reference. The values are Y and N
Alarm Profile - Specifies Alarm Severity Assignment Profile (ASAP) name to be
•
used for the system timing and timing reference entity
Primary State - Specifies the new value of primary state. The values are IS and OOS
•
Operate
The Operate displays the following as shown in
............................................................................................................................................................................................................................................................
3 - 76
Figure
3-71.