Alcatel-Lucent 1850 User Provisioning Manual page 142

Transport service switch
Table of Contents

Advertisement

Menu bar
............................................................................................................................................................................................................................................................
Clock Mode Status - Specifies the currently used operation mode for the system
timing. The values are LOCKED, AUTONOMOUS-HOLDOVER, AUTONOMOUS-
FREERUNNING, FORCEDFREERUNNING
Sync Messaging - Determines if the timing reference selection for system timing is
using sync messaging. The values are Y and N
Alarm Profile - Specifies Alarm Severity Assignment Profile (ASAP) name to be
used for the system timing and timing reference entity
Active Reference - Specifies the AID of the currently selected timing reference for the
system timing
Reference Switch State - Specifies the currently active switch request state of
reference selection for the system timing. The values are NR, MANUAL, and
FORCED
System Timing Quality - Specifies the actual quality value level for the stem timing.
The values in SDH mode are PRC, SSUL, SSUT, SEC, and DUS
The Reference Timing Entities table contains the following parameters:
Select - contains a check box used to identify the Access Identifier used with Modify,
Operate, and Release
Access Identifier - Specifies timing entity facility
Assigned Port Access Identifier - Specifies the Access Identifier of the port
Provisioned Quality level - Specifies the provisioned quality level of a timing
reference. The values are in SDH mode AUTO, PRC, SSL, SSUT, and SEC
Timing Reference Priority - Specifies the priority of a timing reference as forwarded
to the system timing selection process. The values are 0-8
Outgoing Quality - Specifies the actual quality value level for the timing reference as
forwarded to the system timing selection process. The values are in SDH mode PRC,
SSUL, SSUT, SEC, and DUS
Timing Reference Status - Specifies the actual signal status for the timing reference
as forwarded to the system timing and output timing selection process. The values are
NORMAL, SF, WTR, and NA
Timing Reference Lockout - Specifies whether a lockout command for the system
timing selection is present for the timing reference. The values are Y and N
Alarm Profile - Specifies Alarm Severity Assignment Profile (ASAP) name to be
used for the system timing and timing reference entity
Primary State - Specifies the new value of primary state. The values are IS and OOS
Operate
The Operate displays the following as shown in
............................................................................................................................................................................................................................................................
3 - 76
Figure
3-71.
Synchronization menu
8DG08763KAAA
Issue 1 February 2009