Alcatel-Lucent 1850 User Provisioning Manual page 240

Transport service switch
Table of Contents

Advertisement

Tree area
............................................................................................................................................................................................................................................................
Figure 4-28 PM Init Register - STM PM
The Initialize Register panel displays the following parameters:
Access Identifier - Specifies the Access Identifier for the selected STMn port.
Monitor Value - Specifies the monitor value for the selected STM port. The default
value is 0.
Location - Specifies the location. The values are NEND, FEND, BIDIR, and ALL.
The default value is NEND.
Monitored parameter type - Specifies the parameter type to be monitored. The
values are:
– ALL
– OFS-RS
– ES-RS
– SES-RS
– BBE-RS
– UAS-RS
– ES-MS
– SES-MS
– BBE-MS
– UAS-MSB. The default value is ALL.
Direction - Specifies the direction. The values are RCV, TRMT, and ALL. The default
value is RCV.
Time period - Specifies the time interval for the which the report is being generated.
The values are 15-MIN or 1-DAY. The default value is 15-min.
The Save link allows to store all the selections.
PM mode tab
The PM Mode tab allows the user to set and retrieve the performance monitoring mode
for the selected STMn port as shown in
............................................................................................................................................................................................................................................................
4 - 42
Figure
4-29.
Access a module
8DG08763KAAA
Issue 1 February 2009