Alcatel-Lucent 1850 User Provisioning Manual page 489

Transport service switch
Table of Contents

Advertisement

Appendix
............................................................................................................................................................................................................................................................
SGEO shall be set when the supporting IOC is OOS for any reason; SGEO shall clear
FAF while set
TRM shall be set if a supported facility is connected
LPBK shall be set if a loopback is present on this facility
PMI shall be set if performance monitoring is inhibited on this facility
When a port that can be provisioned for more than one OC rate is provisioned for one
rate, the facilities for the other rates return to DSBLD state.
A facility that is entered with failure will first pass to OOS-MA or IS, then to OOSAU,
FAF after the failure integration period, normally 2.5 seconds
State Transition of GBE (GIGE)
Figure 6-19 GBE facility provisioning state transitions
Other Secondary States
1. SDEE shall be set when supported facilities are created.
2. SGEO shall be set when the supporting GBE card\ is OOS for any reason; SGEO
3. TRM shall be set if a supported facility is cross connected
4. PMI shall be set if performance monitoring is inhibited on this facility
5. A facility that is entered with failure will first pass to OOS-MA or IS, then to
............................................................................................................................................................................................................................................................
8DG08763KAAA
Issue 1 February 2009
shall clear FAF while set
OOSAU, FAF after the failure integration period, normally 2.5 seconds
Facility state transitions
6 - 9 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tss-320Tss-160

Table of Contents