Tree area
............................................................................................................................................................................................................................................................
Actual Type - Specifies the acronym of the physically equipped module type (Remote
Inventory data). ANY-<type> is the value shows for a generic non Alcatel-Lucent
XFP/SFP module.
Primary/secondary state - Specifies primary and the secondary service state. Valid
for all modules except TBUS (it has only IS and OOS-AU) and Shelf (it has only IS
and OOS-AUMA). The values are previously described in
Primary state - To change the primary service state previously referred and described.
Automatic In Service Mode - To set the Automatic in service mode to which the
equipment is set. The choices are:
– NOWAIT - A condition notifies the module is unplugged
– AINS - No condition is sent due to module unplugged
Auto-Provisioning - Specifies the Auto provisioning parameter is used to manage the
Autoprovisioning functionality in case of global (Shelf/NE level) restart: its main
purpose is to prevent the autoprovisioning of a Card (after a restart) in a slot position in
which it has been Logically Deleted. It cannot be provisioned, it is managed only by
the NE but can be retrieved. The choices are:
– ON - Autoprovisioning Allowed in that slot position
– OFF - Autoprovisioning Not-Allowed in that slot position
Region - the default value is ETSI
Command Mode - To change the status of the unit. The choices are:
– NORM (normal)
– FRCD (forced)
Output Power Level - Specifies the level of power output.
Alarm Profile: Specifies the Alarm Severity Assignment profile (ASAP) name to use
with this equipment entity. <userlabel> 1-40 alphanumeric characters (plus '-')
assigned as the userlabel for the desired profile. Click Select hyperlink select a
different profile.
The panel has the following hyperlinks:
Save - Applies the selections and restart with new selection
Remove - Causes the specified equipment to be placed in the out-of-service management
service state.
Remote Inventory - Causes the Remote Inventory window opening for the specified
physical entity (refer to
Restart panel
This panel allows to restart or reboot the application. It contains the following parameters:
Access Identifier - Specifies the access identifier of the selected board.
Phase - To change the phase of the unit.
Command Mode - To change the status of the unit. The choices are:
............................................................................................................................................................................................................................................................
8DG08763KAAA
Issue 1 February 2009
Table , "UP > Rack x > Shelf x > Board xx panel" (p.
Access a module
on page
55:
4-55)).