Appendix
............................................................................................................................................................................................................................................................
Command
ENT-FFP-STMn
ENT-FFP-TMPLS
............................................................................................................................................................................................................................................................
8DG08763KAAA
Issue 1 February 2009
Description
Protection type.
Specifies the revert time in
minutes when RVRTV=Y. This
parameter is only applicable to
LINEAR and 2WAYDC cross-
connections in BLSR.
Local Node Identifier, identifies
the node identifier of the BLSR
node.
Applies only to PTYPE=BLSR2.
Symbolic name/description of the
node. Up to 255 characters are
allowed. See Introduction to I/O
manual for valid character set. The
characters must be enclosed
within quotes. This parameter
applies only to BLSR. It is
recommended that ASCII
printable characters be used with
SPACE character as an exception.
Creates a facility protection group. TID
Parameter defaults
Parameter
Default
PTYPE
<entry required>
RVRTTIM
5 if PTYPE =
BLSR2 or
LINEAR;
Otherwise
<NoVal>
NODEID
0 if PTYPE =
BLSR2; Otherwise
<NoVal>
NODEDESC
<NULL>
R
Entry Required
6 - 1 4 7