Procedures
............................................................................................................................................................................................................................................................
Create TCA profile
Purpose
This procedure allows to create a new Threshold Crossing Alarm (TCA) profile instance
of a specified profile type. The new instance of TCAP is created as a clone of the factory
default TCAP of the specified type.
The system can support up to 128 total instances of TCA profile for all facility types.
Note, however, that for STMn facilities, creating a new TL1 instance of a TCA Profile will
use up two (2) internal instances, thus reducing the total number of remaining available
TCA profiles by two.
The access identifier is assigned by the NE with a sequence index number starting from 2,
because indexes 0 and 1 are respectively used for the null and factory default TCAP, for
each TCAP type.
........................................................................................................................................................................................................................
1
Select Alarm --> TCA Profile option from the Menu bar as shown in
Figure 5-48 TCA profile
........................................................................................................................................................................................................................
2
Table 5-28
parameters.
............................................................................................................................................................................................................................................................
8DG08763KAAA
Issue 1 February 2009
"Filter panel parameters"
provides the description of Filter panel
Create TCA profile
Figure
5-48.
5 - 6 1