208 Error Code
Displays a number that describes the error code that was issued when either
SP5816-204 or SP5816-207 was executed.
Cause
Illegal Modem
Parameter
Operation Error,
Incorrect Setting
Operation Error,
Incorrect Setting
Error Caused by
SM Appendix
Code
Meaning
-11001
Chat parameter error
-11002
Chat execution error
-11003
Unexpected error
Inquiry, registration attempted without
-12002
acquiring device status.
Attempted registration without execution
-12003
of an inquiry and no previous
registration.
Attempted setting with illegal entries for
-12004
certification and ID2.
@Remote communication is prohibited.
-12005
The device has an Embedded RC
gate-related problem.
A confirmation request was made after
-12006
the confirmation had been already
completed.
The request number used at registration
-12007
was different from the one used at
confirmation.
Update certification failed because
-12008
mainframe was in use.
ID2 mismatch between an individual
-12009
certification and NVRAM
-12010
Certification area is not initialized.