System SP1-xxx
1106
[Fusing Temp. Display]
001 Center
002 End
003 Pressure
004 Pressure End
1107
[Standby Target Temp. Setting]
Standby Heater Off Time
001
Specifies the time that the fusing heater turns off after the fusing unit
temperature has reached its target temperature.
Stanby/Preheat1: Press
002
Specifies the temperature of the pressure roller for the ready or energy save 1
mode.
Preheat2:Press
004
Specifies the temperature of the pressure roller for the energy save 2 mode.
Low Power:Press
006
Specifies the temperature of the pressure roller for the low power mode.
Print Ready:Center
007
Specifies the temperature of the heating roller for the print ready condition.
Print Ready:Press
008
Specifies the temperature of the pressure roller for the print ready condition.
D086/D087
-
[-10 to 250 / - / 1 deg/step]
Displays the temperature of the heating
-
roller.
-
[-10 to 250 / - / 1 deg/step]
Displays the temperature of the heating
-
roller.
*ENG
[0 to 100 / 15 / 1 sec/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 60 / 1 deg/step]
*ENG
[120 to 180 / 150 / 1 deg/step]
*ENG
[100 to 200 / 120 / 1 deg/step]