System SP3-xxx
008 Upper Counter: C
009 Upper Counter: Y
010 Lower Counter: Bk
011 Lower Counter: M
012 Lower Counter: C
013 Lower Counter: Y
[TD Sensor Initial Set] Developer Initialization Setting
3021
Specifies the developer agitation time for each color at the developer
initialization. DFU
001 Agitation Time: Bk
002 Agitation Time: M
003 Agitation Time: C
004 Agitation Time: Y
005-008 Sets the execution flag of the developer initialization for each color.
005 Execution Flag: Bk
006 Execution Flag: M
007 Execution Flag: C
008 Execution Flag: Y
009 Prohibition
D086/D087
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 200 / 30 / 1 sec/step]
*ENG
*ENG
*ENG
[0 or 1 / 0 / 1/step]
*ENG
0: Flag OFF, 1: Flag ON
This flag is cleared after executing TD
*ENG
sensor initialization.
*ENG
Enables or disables developer
initialization. DFU
*ENG
[0 or 1 / 0 / 1/step]
0: Enable, 1: Disable
3-140