1952
[Fan Control Off Mode Time Set]
001 -
1953
[Extra Fan Control]
Extra Fan Cooling State
001
Displays the extra fan cooling is On or Off.
Extra Fan Cooling: Time:
Threshold
002
Specifies the judgement time for entering the extra fan rotation mode.
Extra Fan Cooling: Rotat:
Threshold
003
Specifies the threshold rotation of the black development unit for entering the
extra fan rotation mode.
Extra Fan Cooling: Start
004
Date
Extra Fan Cooling Time
005
Specifies the execution time for the extra fan cooling.
[Extra Fan Control]
1954
Specifies the execution time of the extra fan rotaion mode for each fan motor.
Fan Cooling Time:Fusing
002
Exit Fan:Initial
Fan Cooling Time:Main
006
Suction Fan:Initial
Fan Cooling Time:Paper
007
Exit Fan:Initial
008 Fan Cooling Time:PSU
SM Appendix
*ENG
[0 to 60 / 10 / 1 min./step]
[0 or 1 / 0 / 1 /step]
*ENG
0: Off, 1: On
[0 to 180 / C2.5a: 110, C2.5b: 100 / 1
*ENG
min./step]
*ENG
[0 to 999999999 / 0 / 1 mm/step]
Displays the execution time and date of
*ENG
the extra fan cooling.
*ENG
[0 to 120 / 30 / 0.1 min./step:
*ENG
[0 to 120 / 0 / 0.1 min./step]
*ENG
[0 to 120 / 0 / 0.1 min./step]
*ENG
[0 to 120 / 0 / 0.1 min./step]
*ENG
[0 to 120 / 0 / 0.1 min./step]
3-39