Ricoh Aficio MP C3001 Service Manual page 1679

Hide thumbs Also See for Aficio MP C3001:
Table of Contents

Advertisement

4.4 NCU PARAMETERS
The following tables give the RAM addresses and the parameter calculation units that the
machine uses for ringing signal detection and automatic dialing. The factory settings for
each country are also given. Most of these must be changed by RAM read/write (SP2-102),
but some can be changed using NCU Parameter programming (SP2-103, 104 and 105); if
SP2-103, 104 and 105 can be used, this will be indicated in the Remarks column. The
RAM is programmed in hex code unless (BCD) is included in the Unit column.
The following addresses describe settings for the standard NCU.
Change the fourth digit from "5" to "6" (e.g. 680500 to 680600) for the settings for
the first optional G3 interface unit and from "5" to "7" (e.g. 680700) for the settings
for the second optional G3 interface unit.
Address
680500
Country/Area code for NCU parameters
Use the Hex value to program the country/area code directly into this
address, or use the decimal value to program it using SP2-103-001
Country
/Area
France
Germany
UK
Italy
Austria
Belgium
Denmark
Finland
SM
Function
Decimal
Hex
00
00
01
01
02
02
03
03
04
04
05
05
06
06
07
07
131
NCU Parameters
Country
Decimal
/Area
USA
17
Asia
18
Hong Kong
20
South Africa
21
Australia
22
New Zealand
26
Singapore
24
Malaysia
25
Hex
11
12
14
15
16
17
18
19
D393