Permit
Temp.:Delta:Press:M-humid:No
006
Decurl
Specifies the threshold temperature for the no curl control in middle humidity.
Permit
Temp.:Delta:Press:H-humid:No
007
Decurl
Specifies the threshold temperature for the no curl control in high humidity.
CPM:M-humid
008
Specifies the CPM ratio of the decurl control against to the normal operation in
middle humidity.
CPM:H-humid
009
Specifies the CPM ratio of the decurl control against to the normal operation in high
humidity.
CPM:M-humid:No Decurl
010
Specifies the CPM ratio against of the no decurl control to the normal operation in
middle humidity.
CPM:H-humid:No Decurl
011
Specifies the CPM ratio against of the no decurl control to the normal operation in
high humidity.
SM Appendix
*ENG
[0 to 200 / 50 / 1 deg/step]
*ENG
[0 to 200 / 40 / 1 deg/step]
*ENG
[0 to 100 / 80 / 1 %/step]
*ENG
[0 to 100 / 65 / 1 %/step]
*ENG
[0 to 100 / 80 / 1 %/step]
*ENG
[0 to 100 / 65 / 1 %/step]
3-19
System SP1-xxx
D086/D087