Ricoh Aficio MP C3001 Service Manual page 1025

Hide thumbs Also See for Aficio MP C3001:
Table of Contents

Advertisement

2013
[Environmental Correction: PCU]
Current Environmental:
001
Display
002 Forced Setting
Absolute Humidity:
003
Threshold 1
Absolute Humidity:
004
Threshold 2
Absolute Humidity:
005
Threshold 3
Absolute Humidity:
006
Threshold 4
007 Current Temp.: Display
Current Relative
008
Humidity: Display
009 Current Absolute
SM Appendix
Displays the environmental condition,
which is measured in absolute humidity.
[1 to 5 / – / 1 /step]
1: LL (LL <= 4.3 g/m
*ENG
2: ML (4.3 < ML <= 11.3 g/m
3: MM (11.3 < MM <= 18.0 g/m
4: MH (18.0 < MH <= 24.0 g/m
5: HH (24.0 g/m
Selects the environmental condition
manually.
[0 to 5 / 0 / 1 /step]
*ENG
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Changes the humidity threshold
*ENG
between LL and ML.
[0 to 100 / 3.0 / 0.01 g/m
Changes the humidity threshold
*ENG
between ML and MM.
[0 to 100 / 8.0 / 0.01 g/m
Changes the humidity threshold
*ENG
between MM and MH.
[0 to 100 / 15.0 / 0.01 g/m
Changes the humidity threshold
*ENG
between MH and HH.
[0 to 100 / 15.0 / 0.01 g/m
Displays the current temperature.
*ENG
[0 to 100 / 0 / 1 deg/step]
Displays the current relative humidity.
*ENG
[0 to 100 / 0 / 1%RH/step]
*ENG
Displays the absolute humidity.
3-45
System SP2-xxx
3
)
3
)
3
)
3
)
3
< HH)
3
/step]
3
/step]
3
/step]
3
/step]
D086/D087

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aficio mp c3501

Table of Contents