System SP2-xxx
2112
[TM/ID Sensor Check] ID Sensor Check FA
001 Execute
[Skew Adjustment]
Specifies a skew adjustment value for the skew motor M, C or Y.
2117
These SPs must be used when a new laser optics housing unit is installed or
when SC285 occurs. For details, see "Laser Optics Housing Unit" in the
"Replacement and Adjustment" section.
001 Pulse: M
002 Pulse: C
003 Pulse: Y
2118
[Skew Adjustment]
001 Execute: M
002 Execute: C
003 Execute: Y
D086/D087
This SP is used to check the ID sensors at
the factory. The results of this SP are
displayed in SP2140 to SP2145.
*ENG
*ENG
[–100 to 100 / 0 / 1 pulse/step]
*ENG
*ENG
Changes the current skew adjustment
values to the values specified with SP2117.
*ENG
These SPs must be used when a new laser
optics housing unit is installed or when
SC285 occurs. For details, see "Laser
*ENG
Optics Housing Unit" in the "Replacement
and Adjustment" section.