Page: Stand-By: FC
Adjusts the threshold of the line position adjustment for BW printing mode in
007
stand-by mode. The line position adjustment is done when the number of
outputs in color printing mode reaches the value specified with this SP and the
condition of SP2-193-008 or SP2-193-009 is satisfied.
Temp.
Adjust the temperature change threshold for the line position adjustment
008
(Mode b: adjustment once). The timing for line position adjustment depends on
the combinations of several conditions. Section Descriptions" section.
Time
Adjust the time threshold for the line position adjustment (Mode b: adjustment
009
once). The timing for line position adjustment depends on the combinations of
several conditions.
Magnification
Adjusts the magnification threshold for line position adjustment. If the length of
010
the main scan is changed by this amount since the previous MUSIC, then
MSUIC is done again.
Temp. 2
Adjust the temperature change threshold for the line position adjustment
011
(Mode a: adjustment twice). The timing for line position adjustment depends on
the combinations of several conditions.
Time 2
Adjust the time threshold for the line position adjustment (Mode a: adjustment
012
twice). The timing for line position adjustment depends on the combinations of
several conditions.
SM Appendix
*ENG
[0 to 999 / 100 / 1 page/step]
*ENG
[0 to 100 / 5 / 1deg/step]
*ENG
[1 to 1440 / 300 / 1 minute/step]
*ENG
[0 to 1 / 0.1 / 0.01%/step]
*ENG
[0 to 100 / 10 / 1deg/step]
*ENG
[1 to 9999 / 600 / 1 minute/step]
3-73
System SP2-xxx
D086/D087