2912
[Offset Amplitude Setting] DFU
001 Y Drum
002 C Drum
003 M Drum
004 K Drum
2913
[Drum Control]
001 Rotation Direction
2920
[Transfer Motor Control]
0: Encorder 1 :FG
001
Selects the speed control mode for the ITB.
If SC443 occurs and machine does not recover, change this setting to "1".
SC443 Count
002
Displays the number of the ITB encodre error. SC443 is displayed if this
counter counts to "3".
[SecondaryFB: Threshold] Paper Transfer Roller Feed-back: Threshold
Adjustment
2930
Adjusts the threshold between high resistance (division 1) and low resistance
(division 2) at the paper transfer roller. This SP affects SP2931 to SP2939.
001 Voltage
2960
[Process Interval]
Additional Time
001
Adjusts the additional time for ending the machine's process.
SM Appendix
*ENG
*ENG
[0 to 100 / 0.0 / 0.1
*ENG
*ENG
*ENG
[0 or 1 / 1 / -/step]
*ENG
[0 or 1 / 0 / 1 /step]
*ENG
[0 to 3 / 0 / 1 /step]
*ENG
[0 to 7000 / 6000 / 10 –V/step]
*ENG
[0 to 10 / 0 / 1 sec/step]
3-133
System SP2-xxx
m/step]
D086/D087