*4* FUNCTION 05 200PWM Density Auto Correction

You must execute this mode in combination with PD density auto correction
I
and 600PWM density auto correction.
Item
200PWM density
auto correction
A, B, and D are approximate values so that optimum images may still be
Note:
obtained even if the values are outside the range; you may omit "temporary
remedy" as long as the images are optimum.
48
TSM Océ 3121
Description
1) Start '200PWM PRINT'.
A 15-gradation test pattern will be generated.
I
2) Place a pile of 5 white sheets on the glass platen.
Then, start 'WHITE MEASURE'.
The scanner makes a single scan.
I
3) Place the 15-gradation test sheet on the glass
platen. Then, start 'DENSITY MEASURE' .
4)Check the values under A, B, and D:
20 <= A <=50
–40 <= B <= 40
0 <= D <= 8
5)If the values are as indicated, press 'DATA SET'
to highlight, and press the OK key.
Remarks
A, B or D not
OK:
suspect:
drum unit
I
scanning
I
lamp
laser unit
I
composite
I
power sup-
ply
analog
I
processor
PBA
image proc-
I
essor PBA
See note