E007-01 The Fixing Film Does Not Realign - Oce 3121 Technical & Service Manual

Table of Contents

Advertisement

5 E007-01 The fixing film does not realign.

Cause
Front cover (the
switch actuator)
Roller
Fixing film
Releasing lever
Detect lever
Film sensor PS2
M5 Fixing film
motor
16
TSM Océ 3121/3122
Step Checks
1
Switch OFF. Is the switch
actuator damaged?
2
Have any of the rollers
slipped off? The lower
roller, the tension roller
or the cleaning roller.
3
Is the film cut, or bent, or
torn?
4
Have more than 200,000
copies been made with
the fixing unit?
5
Is the releasing lever
faulty?
6
Is the tension spring of
the detect lever in good
condition? Also, does it
move smoothly?
7
Is the sensor PS2 in good
condition?
8
Turn on the main power,
and reset the error using
'ERROR' in service
mode (*4*). When the
main power turns off
automatically thereafter,
turn it on once again, and
execute 'FILM COME-
BACK' in service mode
(*4*). Is the operation of
the fixing film motor
(M5) normal?
Yes/No
Action
Yes
Replace the front cover.
Yes
Replace the fuser unit.
Yes
Replace the fuser unit.
Yes
Replace the fuser unit.
Yes
Replace the fuser unit.
No
Correct it.
No
Check the wiring
between: the DC control
PBA, via the connector
J47, to the sensor. If
undamaged, replace the
sensor.
No
Replace the motor (M5).
Yes
Replace the fuser unit.
Error code solving / machine fault solving

Advertisement

Table of Contents
loading

This manual is also suitable for:

3122