Cause
Output level (sen-
sor)
Sensor

27 E500/E713

Cause
Communication
cable: to the copier
Multi tray commu-
nication mode
Circuit breaker CB1 2
Resistor R12, on
the tray control
PBA
24V power supply
28
TSM Océ 3121/3122
Step Checks
4
After steps 2 and 3, check the
output according to the table in
step 1. Is the reading of the
meter 1.2 V or lower?
5
Perform step 4. Is the problem
corrected?
Step Checks
1
Check the connection of
the communication cable,
between the copy data
controller and the copier.
1
Is the mode set correctly?
Use the DIP switch, on
the tray control PBA, to
set the mode.
Press the circuit breaker
CB1, on the tray control
PBA. Is the problem cor-
rected?
3
Check the continuity over
the resistor R12, on the
tray control PBA.
Approximately 2.2 Ohm?
4
Set the meter to the DC
range. Connect the + to
J1-2 and the – to J1-1 on
the tray control PBA.
Does the voltage change
to approximately 24 V?
Y/N Action
No
Mount the sensor cor-
rectly.
Yes
End.
No
Replace the sensor.
(After replacement, be
sure to adjust each sen-
sor.)
Yes/No
Action
No
Connect the cable cor-
rectly.
No
Reset the mode set.
Yes
End.
No
Replace the tray control
PBA.
No
Check the copier's 24V
power supply.