E110 Scanner Motor Fails; E190 Ram Error - Oce 3121 Technical & Service Manual

Table of Contents

Advertisement

13 E110 Scanner motor fails

Cause
Step
1
J153
2
DC power
3
supply
Laser scan-
ner drive
PBA, laser
scanner unit
DC control
4
PBA
Laser unit

14 E190 RAM error.

Cause
Step
1
Image proc-
2
essor PBA
DC control
PBA
ed.2
Checks
Inspect the connection of
J153, to the laser driver PBA.
Perform key operation during
stand-by. Is the sound of the
rotation of the laser scanner
motor heard?
Is there a power supply to the
laser driver PBA?
J152 1 = 24 V.
I
J152 2 = 0 V.
I
Replace the DC control PBA.
Is the problem corrected?
Checks
Switch OFF, then ON. Is the
problem corrected?
Execute 'IP-CHK' in service
mode (*4*). Is 'OK' indi-
cated after execution?
Yes/No Action
No
Connect the connector.
Yes
Go to step 4.
Check the wiring
No
between the connector
J152 on the laser scan-
ner driver PBA to the
connector J204-5/-6 on
the composite power
supply PBA .
Yes
Try replacing the follow-
ing items:
Laser scanner drive
I
PBA
Laser unit
I
Yes
End
No
Replace the laser unit
Yes/No Action
Yes
End
No
Replace the image proc-
essor PBA
Yes
End if the problem is
corrected after turning
OFF/ON the main
power supply. If 'E190'
is indicated, replace the
DC controller PBA.
Trouble shooting 21