Communication Errors E710 (The Ipc Communication Chip On The Image Processor Pba Has A Fault.); E711, E712, E713, E716 (Ipc Communication Error); E717 Error In The Communication With The Copy Data Controller - Oce 3121 Technical & Service Manual

Table of Contents

Advertisement

40 Communication Errors E710 (The IPC communication chip on
the image processor PBA has a fault.)
Cause
Step
1
Image proces-
sor PBA

41 E711, E712, E713, E716 (IPC communication error)

Cause
Step
1
DC control
PBA

42 E717 Error in the communication with the copy data controller.

Cause
Step
1
2
Copy Data
Controller
DC control
PBA
36
TSM Océ 3121/3122
Checks
Turn off and then on the main
power supply. Is the problem
corrected?
Checks
Switch OFF, then ON. Is the
problem solved?
Checks
Clear 'E717' by executing
'ERROR' in service mode
(*4*); thereafter, turn
OFF/ON the main power sup-
ply. Is the problem corrected?
Replace the Copy Data Con-
troller. Is the problem cor-
rected?
Yes/No Action
YES
End.
NO
Check that the image
processor PBA is free of
dust or foreign matter;
then, replace the image
processor PBA
Yes/No Action
Yes
End
No
Replace the DC control
PBA
Yes/No Action
Yes
End
Yes
End
No
Replace the DC control
PBA