Adjustments
1 The position of the deflection solenoid SL5
Remove the output unit
1
Place the output unit vertically on a level surface.
2
Press the plunger of the solenoid SL5 as far as it will go.
3
The gap between the ring on the plunger and the housing of the solenoid should
4
be 0.2 mm. If necessary, loosen the screws and adjust the position of the sole-
noid.
Refit the output unit.
5
Solenoid for the paper deflector SL5
ed.1
Paper deflecting plate 1 solenoid (SL5)
0.2 mm
0.2mm