7. Input and Output Check
A3LCT-CPU-PortB
086
Checks if Tray is set.
A3LCT-CPU-PortC
087
Checks if Feed Unit is set.
A3LCT-CPU-PortD
088
Checks Not Normal/Normal condition for Feed Motor.
706
[0 to 255 / 0 / 1/step]
• Bit 0: -
• Bit 1: -
• Bit 2: -
ENG
• Bit 3: -
• Bit 4: -
• Bit 5: Tray Set (0: Set, 1: Unset)
• Bit 6: -
• Bit 7: -
[0 to 255 / 0 / 1/step]
• Bit 0: -
• Bit 1: -
• Bit 2: -
• Bit 3: Feed Unit Set Detection
ENG
(0: Set, 1: Unset)
• Bit 4: -
• Bit 1: -
• Bit 6: -
• Bit 7: -
[0 to 255 / 0 / 1/step]
• Bit 0: Feed Motor FAULT (0:
Normal, 1: Not Normal)
• Bit 1: -
• Bit 2: -
ENG
• Bit 3: -
• Bit 4: -
• Bit 1: -
• Bit 6: -
• Bit 7: -