Ricoh MP C6502SP System Maintenance page 245

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

-
001
Sets the alarm to sound for the specified jam level (document miss feeds are not included).
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
5505
counter decreases by "1" when an SC is not detected during a set number of copied sheets
(for example, default 700 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 Error Alarm
[Supply/CC Alarm]
5507
Enables or disables the sending of supply calls via @Remote.
001 Paper Supply Alarm
002 Staple Supply Alarm
Toner Supply Alarm
003
If you select "1" the alarm will sound when the copier detects toner end.
[0 to 3 / 3 / 1/step]
0: Zero (Off)
*CTL
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
[0 to 255 / 19 / 1hundred/step]
*CTL
0: Alarm Off
[0 or 1 / 0 / 1/step]
*CTL
0: OFF
1: ON
[0 or 1 / 1 / 1/step]
*CTL
0: OFF
1: ON
[0 or 1 / 1 / 1/step]
*CTL
0: OFF
1: ON
SP5-009 to 721 (Mode)