Ricoh MP C6502SP System Maintenance page 131

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

Factory :L:GE
Display/Saves Factory SSCG Digital correction value (L Side/GREEN/EVEN pixel).
009
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
Factory :L:GO
Display/Saves Factory SSCG Digital correction value (L Side/GREEN/ODD pixel).
010
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
Factory :L:BE
Display/Saves Factory SSCG Digital correction value (L Side/BLUE/EVEN pixel).
011
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
Factory :L:BO
Display/Saves Factory SSCG Digital correction value (L Side/BLUE/ODD pixel).
012
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
4641
[SSCG Noise Amplitude]
F:RE
Displays SSCG Nose Amplitude (F Side/RED/EVEN pixel) when adjusting SSCG.
001
Correction value will be decided depending on detected Noise Amplitude when adjusting.
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
F:RO
Displays SSCG Nose Amplitude (F Side/RED/ODD pixel) when adjusting SSCG.
002
Correction value will be decided depending on detected Noise Amplitude when adjusting.
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[0 to 1023 / 0 / 1digit/step]
ENG
[0 to 1023 / 0 / 1digit/step]