Ricoh MP C6502SP System Maintenance page 126

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

2. Main SP Tables-4
Latest:L:BO
Displays SSCG analog correction value (L Side/BLUE/ODD pixel).
012
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
4638
[SSCG Noise Cancel (Digital)]
Latest:F:RE
Displays SSCG Digital correction value (F Side/RED/EVEN pixel).
001
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
Latest:F:RO
Displays SSCG Digital correction value (F Side/RED/ODD pixel).
002
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
Latest:F:GE
Displays SSCG Digital correction value (F Side/GREEN/EVEN pixel).
003
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
Latest:F:GO
Displays SSCG Digital correction value (F Side/GREEN/ODD pixel).
004
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
Latest:F:BE
Displays SSCG Digital correction value (F Side/BLUE/EVEN pixel).
005
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
124
ENG
[-31 to 31 / 0 / 1digit/step]
*ENG
[-255 to 255 / 0 / 1digit/step]
*ENG
[-255 to 255 / 0 / 1digit/step]
*ENG
[-255 to 255 / 0 / 1digit/step]
*ENG
[-255 to 255 / 0 / 1digit/step]
*ENG
[-255 to 255 / 0 / 1digit/step]