Ricoh MP C6502SP System Maintenance page 10

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

1. Main SP Tables-3
60 and lager
Potential adjust
90 and lager
Result(End)
• Execute result sample (In order of YMCK from left)
• Factory default(SP default):[00,00,00,00]
• Starting adjust:[99,99,99,99]
• Fail Vsg adjust(Y):[21,99,99,99]
• Error of Develop gamma Max(C):[99,99,55,99]
• Succeed:[11,11,11,11]
[Process Setup :Exe]
Executes Process Initial Setup. (the mode executing agent agitation, Charge AC
3020
Adjustment, Charge R Cleaning, Transfer Current Adjustment, Toner Density Adjustment
Process Control, and MUSIC collectively)
001 Execute: ALL
[Developer Fill :Exe]
3024
Executes when filling Developer. (the mode filling Development Unit with Developer)
Execute: ALL
001
Executes when filling Developer. (the mode filling Development Unit with Developer)
8
61
LD won't light
62
Residual potential:Vr error
Electrified potential:Vd adjust
63
error
Exposure potential:Vpl adjust
64
error
90
Potential not adjust
99
Kill
ENG
ENG
P patter is not written.
Vr>Max
Vd can not be adjusted in target
range.
Vpl can not be adjusted in
target range
Potential control method is set
as [0:FIX]
Kill by door open, power off,
error.
(Set when execute.)
[- / - / -]
[Execute]
[- / - / -]
[Execute]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents