Ricoh MP C6502SP System Maintenance page 70

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

1. Main SP Tables-3
Threshold : Volume Count : full
012
Threshold for Full detection. Displays Waste Toner Volume Threshold for Full from Mecha
Detection.
Threshold : Volume Count : empty
013
Threshold for New Part detection. Displays Waste Toner Volume Threshold from Near Full
and Full to New Part.
Threshold : Remainder days
014
Displays the threshold for remainder days indicating the timing to display the Near Full
message after Mecha Detection.
Solid M/A
021
Solid M/A
68
[0.0 to 10000000.0 / 480000.0 /
0.1mg/step]
Value increase: Upper limit for Waste
Toner Volume from Mecha Detection
*ENG
increases.
Value decrease: Upper Limit for Waste
Toner Volume from Mecha Detection
decreases.
[0.0 to 10000000.0 / 960000.0 /
0.1mg/step]
Value increase: Printed pages until when
the machine recognizes that the new
*ENG
bottle is set increases.
Value decrease: Printed pages until
when the machine recognizes that the
new bottle is set decreases.
[0 to 255 / 15(Office a, Office b),
29(Pro a, Pro b) / 1day/step]
Value increase: The days until when the
Near Full message is displayed after
*ENG
Mecha Detection become short.
Value decrease: The days until when the
Near Full message is displayed after
Mecha Detection become long.
[0.00000 to 1.00000 / 0.00500 /
*ENG
0.00001 mg/mm2]