2. Main SP Tables-4
Mode Selection
001
Selects SSCG Noise Correction Mode.
Use when SSCG does not function correctly due to accidental malfunction, as a temporally
action, set with out adjusting SSCG.
When SSCG does not function correctly, due to scanner, side streak/cross streak might
appear in high density area.
Use this temporally if changing setting redresses problem.
4637
[SSCG Noise Cancel (Analog)]
Latest:F:RE
Displays SSCG analog correction value (F Side/RED/EVEN pixel).
001
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
Latest:F:RO
Displays SSCG analog correction value (F Side/RED/ODD pixel).
002
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
Latest:F:GE
Displays SSCG analog correction value (F Side/GREEN/EVEN pixel).
003
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
Latest:F:GO
Displays SSCG analog correction value (F Side/GREEN/ODD pixel).
004
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
122
[0 to 3 / 1 / 1/step]
0:do not adjust SSCG
*ENG
1: Only adjust analog.(default)
2: Only adjust digital
3: Adjust both analog/digital.
ENG
[-31 to 31 / 0 / 1digit/step]
ENG
[-31 to 31 / 0 / 1digit/step]
ENG
[-31 to 31 / 0 / 1digit/step]
ENG
[-31 to 31 / 0 / 1digit/step]