Ricoh MP C6502SP System Maintenance page 28

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

1. Main SP Tables-3
005 Abs Humid:5
[Env Thresh:Body]
3265
Sets Absolute Humidity Threshold in order to determine the current environment division
based on the detection result of Temperature/Humidity Sensor (Main Unit).
001 Abs Humid:1
002 Abs Humid:2
003 Abs Humid:3
004 Abs Humid:4
005 Abs Humid:5
3300
[ID Pattern :Disp]
M/A(Latest):K
001
Displays the latest ID Pattern M/A (K).
M/A(Latest):C
002
Displays the latest ID Pattern M/A (C).
M/A(Latest):M
003
Displays the latest ID Pattern M/A (M).
M/A(Latest):Y
004
Displays the latest ID Pattern M/A (Y).
26
[0.00 to 100.00 / 25.00 /
*ENG
0.01g/m3/step]
[0.00 to 63.00 / 2.50 / 0.01g/m3/
*ENG
step]
[0.00 to 63.00 / 5.00 / 0.01g/m3/
*ENG
step]
[0.00 to 63.00 / 8.40 / 0.01g/m3/
*ENG
step]
[0.00 to 63.00 / 15.00 / 0.01g/m3/
*ENG
step]
[0.00 to 63.00 / 24.00 / 0.01g/m3/
*ENG
step]
[0.000 to 1.000 / 0.000 /
*ENG
0.001mg/cm2/step]
[0.000 to 1.000 / 0.000 /
*ENG
0.001mg/cm2/step]
[0.000 to 1.000 / 0.000 /
*ENG
0.001mg/cm2/step]
[0.000 to 1.000 / 0.000 /
*ENG
0.001mg/cm2/step]

Hide quick links: