3. Main SP Tables-5
Outside Line Outgoing Number
The SP sets the number that switches to PSTN for the outside connection for embedded
RCG-M in a system that employs a PBX (internal line).
• If the execution of SP5816-151 has succeeded and embedded RCG-M has
connected to the external line, this SP display is completely blank.
154
• If embedded RCG-M has connected to an internal line, then the number of the
connection to the external line is displayed.
• If embedded RCG-M has connected to an external line, a comma is displayed with
the number. The comma is inserted for a 2 sec. pause.
• The number setting for the external line can be entered manually (including commas).
PPPConnectTimeout
155
Modifies connection timeout when RCG-M is accessing to PPP.
Dial Up User Name
Use this SP to set a user name for access to remote dial up. Follow these rules when setting
a user name:
156
• Name length: Up to 32 characters
• Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
Dial Up Password
Use this SP to set a password for access to remote dial up. Follow these rules when setting
a user name:
157
• Name length: Up to 32 characters
• Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
Local Phone Number
Use this SP to set the telephone number of the line where embedded RCG-M is connected.
161
This number is transmitted to and used by the Call Center to return calls. Limit: 24 numbers
(numbers only)
314
*CTL
[4digits / - / 1digit/step]
*CTL
[1 to 65536 / 60 / 1 / step ]
*CTL
[up to 32 char. / - / -/step]
*CTL
[up to 32 char. / - / -/step]
*CTL
[up to 24 numbers / - / -/step]