1. Main SP Tables-3
3152
[Bottle Motor :Set]
On Time
001
Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (Y) after
Toner Near End is fixed.
Off Time
002
Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (Y) after
Toner Near End is fixed.
RecoveryTimes
003
Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (Y) after
Toner Near End is fixed.
Stop Timing :Set
010
Sets the upper limit for Toner Fill Operation by Toner Bottle Motor after Toner Near End is
fixed.
Cnt:K
011
Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (K) after
Toner Near End is fixed.
Cnt:C
012
Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (C) after
Toner Near End is fixed.
Cnt:M
013
Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (M) after
Toner Near End is fixed.
[TnrDensity]
3200
Displays Toner Density (wt%).
001 K
002 C
003 M
004 Y
20
*ENG
[- to - / 400 / 1count/step]
*ENG
[- to - / 400 / 1count/step]
*ENG
[- to - / 140 / 1count/step]
*ENG
[0 to 2000 / 0 / 1count/step]
*ENG
[0 to 2000 / 0 / 1count/step]
*ENG
[0 to 2000 / 0 / 1count/step]
*ENG
[0 to 2000 / 0 / 1count/step]
*ENG
*ENG
[0 to 25.5 / 0 / 0.1 wt%/step]
*ENG
*ENG