Ricoh MP C6502SP System Maintenance page 27

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

Environ:Recent
004
Displays the current environment according to the absolute humidity calculated by
Temperature/Humidity Sensor (Main Unit).
Environ:Recent 2
005
Displays the current environment according to the absolute humidity calculated by
Temperature/Humidity Sensor (Main Unit).
3262
[Env Set:PCU]
Force Settings
001
Forced setting for PCU Environment
3263
[Env Set:Body]
Force Settings
001
Sets forcibly the current environment (Main Unit)
Force Settings 2
003
Sets forcibly the current environment (Main Unit 2)
[Env Thresh:PCU]
3264
Threshold for Environment Division
002 Abs Humid:2
003 Abs Humid:3
004 Abs Humid:4
*ENG
[- / - / -]
ENG
[- / - / -]
[0 to 6 / 0 / 1/step]
ENG
0: Sensor Detection, 2-6: Each
Environment for LL-HH
[0 to 6 / 0 / 1/step]
ENG
0: Sensor Detection, 1-6: Each
Environment for LLL-HH
[0 to 10 / 0 / 1/step]
ENG
0: Sensor Detection, 1-10: Each
Environment for 1-10
[0.00 to 100.00 / 5.00 / 0.01g/m3/
*ENG
step]
[0.00 to 100.00 / 10.00 /
*ENG
0.01g/m3/step]
[0.00 to 100.00 / 18.00 /
*ENG
0.01g/m3/step]
SP3-XXX (Process)
25