2. Main SP Tables-4
Factory Setting:F:GO
Display/Saves White level peak scanning value (F side/GREEN/ODD) for factory light
004
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Factory Setting:F:BE
Display/Saves White level peak scanning value (F side/BLUE/EVEN) for factory light
005
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Factory Setting:F:BO
Display/Saves White level peak scanning value (F side/BLUE/ODD) for factory light
006
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Factory Setting:L:RE
Display/Saves White level peak scanning value (L side/RED/EVEN) for factory light
007
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Factory Setting:L:RO
Display/Saves White level peak scanning value (L side/RED/ODD) for factory light
008
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Factory Setting:L:GE
Display/Saves White level peak scanning value (L side/GREEN/EVEN) for factory light
009
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
182
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]