Ricoh MP C6502SP System Maintenance page 365

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

[1-Pass ADF INPUT Check]
6011
See page 671
[1-Pass ADF OUTPUT Check]
6012
See page 741
[Original Size Detect Setting]
Sets which original size is to be determined in regard to the two original sizes which are
6016
impossible to be determined in ADF. Size for each bit differs depending on destinations.
Sets the bit for default size for "0" when taking priority, and sets for "1" when Switch Size
determines.
001 -
[DF Magnification Adj.]
6017
Executes Magnification fine adjustment. Changes Line Speed along with the Magnification
Setting value.
001 -
[Skew Correction Moving Setting]
Skew Correction Moving (Skew Correction 2) into Interval Sensor Roller in ADF is executed
6020
only for small sizes (B6, A5, HLT) by default. It is possible to set to execute Skew Correction
Moving for all sizes by setting for "1".
001 -
6030
[DF Hinge] (SSP)
Hinge Open Counter
001
Records number of times that hinge opened with ADF lift up.
Hinge Open Counter State
002
Records status of open and close DF hinge when main unit is turned OFF.
*ENG
[0 to 255 / 0 / 1/step]
*ENG
[-5.0 to 5.0 / 0.0 / 0.1 %/step]
*ENG
[0 or 1 / 0 / 1/step]
ENG
[0 to 999999 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
SP6-XXX (Peripherals)