14
Error Messages
The following is a list of error messages you may possibly receive while working
with ECDIS and Chart Station. The list provides the warning message, the signi-
fication and the probable cause.
14.1
Warning and Notification Messages
MESSAGES
ANCHOR WATCH ALARM
DEPTH TOO SHALLOW
DR POSITION MONITOR
ALARM
GUARD ZONE ALARM
CONTROL MODE MISMATCH
Edition: 30.MAR.2007
Operator Manual
Figure: 14−1 Error Message in the ECDIS
Table 14−1 Warning and Notification Messages
SIGNIFICATION
Ship moves out of user
defined Anchor Circle
Current depth is less then
alarm depth (shallow water)
Difference between DR
position and input position is to
high
ARPA target is intruding
the guard zone area
Communication ECDIS −
Autopilot is incorrect.
ECDIS
14−1
R
Raytheon Anschütz GmbH
Germany
Alarm Message
with
− error number
− time
− reason
Scroll up and
down
PROBABLE CAUSE
Ship is drifting. Range of
Circle can be changed inside the
Anchor watch dialog
Adjustable in ship info
dialog
Check position input
Enable or Disable function
or change area size in Guard
Zone dialog.
Check ECDIS−Autopilot
connection. Restart ECDIS and
or Autopilot