5.2.6
Overlays
This menu item allows the user to select the SENC information (System
Electronic Navigational Chart) to be displayed on the current chart.
Procedure: (see Figure: 1−18)
Step 1 Select S57 Options (see Figure: 1−1).
Step 2 Select Overlays. The Dialog Box appears.
Base Display permanently retained on the ECDIS display, consisting of:
1 coastline (high water);
2 own ship's safety contour (to be selected by the mariner);
3 indication of isolated underwater dangers of depths less than the safety
4 indication of isolated dangers which lie within the safe water defined by the
5 traffic routing systems;
6 fixed and floating aids to navigation;
3655DOC020102
Operator Manual
Click on Export, to create a file with the contents of the Log
Export
List. For this procedure a formatted 3,5" disk must first of all
be inserted in the drive.
Figure: 1−18
contour which lie within the safe waters defined by the safety contour;
safety contour such as bridges, overhead wires, etc., and including buoys
and beacons whether or not these are being used as aids to navigation;
S57 Overlays
5−20
Edition: 30.MAR.2007