Standard Display to be displayed when the chart is first displayed by ECDIS,
consisting of:
1 the Base Display plus;
2 drying line;
3 boundaries of fairways, channels, etc.;
4 visual and radar conspicuous features;
5 prohibited and restricted areas;
6 chart scale boundaries;
7 indication of cautionary notes;
Full Display all other information which is not part of the Standard Display, for
example:
1 spot soundings;
2 submarine cables and pipelines;
3 ferry routes;
4 contents of cautionary notes;
5 graticule;
6 place names;
User defined Display
This functions allows to restore the user defined display settings by a single
operator action. See S57 Chart Options..., using the command button
Save settings as " User defined Display"
S57 Chart Options....
With this menu item, additional display information can be turned on or off by
pressing the corresponding check boxes. The availability of the check box
groups depends on the pre−selected chart feature set (Base Display / Standard
Display/ Full Display).
The values for 3 different depth contour lines and the safety depth can be set.
Routes and the Antigrounding Searchlight are checked against the Safety
Contour. The safety Contour line is displayed in any mode. The other contour
lines are only used for visual distinction of different depth areas.
Edition: 30.MAR.2007
ECDIS
Operator Manual
.
5−21
R
Raytheon Anschütz GmbH
Germany