12.1.2
Position Monitoring
The Position Monitoring function allows you to select a Deviation Limit value for
heading or track control and additional information about the Current Deviation,
Primary Position and Secondary Position.
Procedure: (see Figure: 12−3)
Step 1 Select Position Monitoring from the Integration menu.
Step 2 Select Enable Position Monitoring Alarm if you want this monitor
Edition: 30.MAR.2007
ECDIS
Operator Manual
The Dialog box appears.
function during heading control.
Enter the desired Deviation Limit directly or use the Spinners.
Step 1
Figure: 12−3
12−5
Step 2
Position Monitoring