from the wire harness.
b. Connect the battery (DC 12 V) as shown.
• Positive battery terminal 
Brown "1"
• Negative battery terminal 
Red "2"
1
c. Check the seat/fuel lid lock solenoid move-
ment.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
EAS32450
CHECKING THE STORAGE COMPARTMENT
LID LOCK SOLENOID (for XP530-A/XP530D-
A)
1. Check:
• Storage compartment lid lock solenoid
Faulty/rough movement  Replace.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Disconnect the storage compartment lid lock
solenoid from the wire harness.
b. Connect the battery (DC 12 V) as shown.
• Positive battery terminal 
Brown "1"
• Negative battery terminal 
Black "2"
1
c. Check the storage compartment lid lock sole-
noid movement.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
Br
R
2
Br
B
2